Testing Methodology

Although the testing of a cooler appears to be a simple task, that could not be much further from the truth. Proper thermal testing cannot be performed with a cooler mounted on a single chip, for multiple reasons. Some of these reasons include the instability of the thermal load and the inability to fully control and or monitor it, as well as the inaccuracy of the chip-integrated sensors. It is also impossible to compare results taken on different chips, let alone entirely different systems, which is a great problem when testing computer coolers, as the hardware changes every several months. Finally, testing a cooler on a typical system prevents the tester from assessing the most vital characteristic of a cooler, its absolute thermal resistance.

The absolute thermal resistance defines the absolute performance of a heatsink by indicating the temperature rise per unit of power, in our case in degrees Celsius per Watt (°C/W). In layman's terms, if the thermal resistance of a heatsink is known, the user can assess the highest possible temperature rise of a chip over ambient by simply multiplying the maximum thermal design power (TDP) rating of the chip with it. Extracting the absolute thermal resistance of a cooler however is no simple task, as the load has to be perfectly even, steady and variable, as the thermal resistance also varies depending on the magnitude of the thermal load. Therefore, even if it would be possible to assess the thermal resistance of a cooler while it is mounted on a working chip, it would not suffice, as a large change of the thermal load can yield much different results.

Appropriate thermal testing requires the creation of a proper testing station and the use of laboratory-grade equipment. Therefore, we created a thermal testing platform with a fully controllable thermal energy source that may be used to test any kind of cooler, regardless of its design and or compatibility. The thermal cartridge inside the core of our testing station can have its power adjusted between 60 W and 340 W, in 2 W increments (and it never throttles). Furthermore, monitoring and logging of the testing process via software minimizes the possibility of human errors during testing. A multifunction data acquisition module (DAQ) is responsible for the automatic or the manual control of the testing equipment, the acquisition of the ambient and the in-core temperatures via PT100 sensors, the logging of the test results and the mathematical extraction of performance figures.

Finally, as noise measurements are a bit tricky, their measurement is being performed only manually. Fans can have significant variations in speed from their rated values, thus their actual speed during the thermal testing is being acquired via a laser tachometer. The fans (and pumps, when applicable) are being powered via an adjustable, fanless desktop DC power supply and noise measurements are being taken 1 meter away from the cooler, in a straight line ahead from its fan engine. At this point we should also note that the Decibel scale is logarithmic, which means that roughly every 3 dB(A) the sound pressure doubles. Therefore, the difference of sound pressure between 30 dB(A) and 60 dB(A) is not "twice as much" but nearly a thousand times greater. The table below should help you cross-reference our test results with real-life situations.

The noise floor of our recording equipment is 30.2-30.4 dB(A), which represents a medium-sized room without any active noise sources. All of our acoustic testing takes place during night hours, minimizing the possibility of external disruptions.

<35dB(A) Virtually inaudible
35-38dB(A) Very quiet (whisper-slight humming)
38-40dB(A) Quiet (relatively comfortable - humming)
40-44dB(A) Normal (humming noise, above comfortable for a large % of users)
44-47dB(A)* Loud* (strong aerodynamic noise)
47-50dB(A) Very loud (strong whining noise)
50-54dB(A) Extremely loud (painfully distracting for the vast majority of users)
>54dB(A) Intolerable for home/office use, special applications only.

*noise levels above this are not suggested for daily use

The DEEPCOOL Captain EX 240 RGB Cooler Testing Results, Maximum Fan Speed
Comments Locked

34 Comments

View All Comments

  • croc - Friday, December 15, 2017 - link

    I have an NHD-15 heat sink and I also have a corsair h80i v2. (my case, a silverstone FT1 does not easily support radiators larget than 120mm) My CPU is an older 3930K six core that warms up nicely... Of course I do not have all the nice test bench stuff that Anandtech has, so my results are quite a bit more touchy-feely. By just a whisker the NHD-15 is both a tad quieter and a tad cooler.... I also like the fact that I know that outside of the fans there are no moving parts to fail.

    I am sure that my limitations are the 120 mm radiator, and I am also pretty well convinced that within a given sized radiator, there will be a very narrow range of test results across the range of AIO kits. But I keep looking...
  • LordanSS - Friday, December 15, 2017 - link

    Thank you, Mr. Fylladitakis for your review.

    Since the advent of AIO liquid cooling kits my personal builds have changed a good bit. Have a H100i on my main build for a few years now, and my old and trusty second machine has a Hyper 212 EVO on it.

    I've had bad experiences with heavy air coolers in the past, so I tend to stay away from them these days. My cases have positive pressure and the H100i works well as an exhaust mounted at the top.

    To each their own. I know several people that frequent this website are still fond of air cooling, and in many situations it's still a very good and efficient option but in the end I'd say it depends on what kind of build you have in mind.
  • snarfbot - Sunday, December 17, 2017 - link

    how long are these coolers being run at load?
  • deadlockedworld - Wednesday, April 11, 2018 - link

    For all the commentary about the bench -- this deepcool is not in the Anandtech bench section. ...

Log in

Don't have an account? Sign up now